Technical Bulletin VLV
Issue Date 0100
© 2004 BASO Gas Products 1
Part No. 24-8711-455, Rev. www.baso.com
Grommet
Blue
Red
Black
To Terminal 1
To Terminal 5
or Ground
Screw B
Screw A
Pilot Tap
Connection
To Terminal 3
Valve
Inlet
Figure 1: Universal Replacement Gas Valve
The VLV49A Series Universal Replacement Gas Valve is for the
replacement of the valve assembly of an electronic proven pilot spark
ignition control with a valve (i.e., G60 and Q15). They are combination
redundant valves, available with or without a pressure regulator.
These valves can be used on appliances burning natural gas, Liquefied
Petroleum (LP) gas, manufactured gas, mixed gas or LP gas-air mixtures,
including sulfur bearing gases (depending on the regulator selection) at
pressures up to 35 mbar (0.5 psi).
VLV49A Series Universal Replacement Gas Valve
Application
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - Issue Date 0100

Technical Bulletin VLV Issue Date 0100 © 2004 BASO Gas Products 1 Part No. 24-8711-455, Rev. ⎯ www.baso.com GrommetBlueRedBlackTo Termin

Strona 2 - Table 1: Specifications

10 VLV49A Series Universal Replacement Gas Valve Technical Bulletin 17. After installation of the replacement valve is complete, except for the a

Strona 3

VLV49A Series Universal Replacement Gas Valve Technical Bulletin 11 IMPORTANT: All adjustments must be made in conjunction with the gas appliance

Strona 4 - (Cont.)

12 VLV49A Series Universal Replacement Gas Valve Technical Bulletin ! WARNING: Fire or Explosion Hazard. Avoid personal injury or property damag

Strona 5

2 VLV49A Series Universal Replacement Gas Valve Technical Bulletin Table 1: Specifications Product VLV49A Series Universal Replacement Gas Valves

Strona 6

VLV49A Series Universal Replacement Gas Valve Technical Bulletin 3 Table 3: Replacement Valve Selection Chart Original Valve/Ignition Part Number

Strona 7 - Termi nals

4 VLV49A Series Universal Replacement Gas Valve Technical Bulletin Original Valve/Ignition Part Number (Cont.) Replacement Valve Part Number G60RH

Strona 8

VLV49A Series Universal Replacement Gas Valve Technical Bulletin 5 Original Valve/Ignition Part Number (Cont.) Replacement Valve Part Number VLV43

Strona 9

6 VLV49A Series Universal Replacement Gas Valve Technical Bulletin IMPORTANT: This technical bulletin is intended as a guide for authorized servi

Strona 10

VLV49A Series Universal Replacement Gas Valve Technical Bulletin 7 4. Disconnect the sensing probe lead from Terminal 4 on the ignition control.

Strona 11

8 VLV49A Series Universal Replacement Gas Valve Technical Bulletin 7. Remove Screws A and B holding the ignition control assembly to the valve an

Strona 12 - PO Box 170

VLV49A Series Universal Replacement Gas Valve Technical Bulletin 9 15. Reconnect the thermostat leads, the sensing probe lead, and the high volta