16 BGH2UNCTRLHT-01 Universal Hot Surface Ignition Control Installation Instructions
Cut out and leave near control.
Green LED Indications During Normal Operation
Steady On Flame detected, Good flame, Main burner on
0.5 Second On, 0.5 Second Off Pre-purge, Between trial purge, Igniter warmup
2 Continuous Quick Flashes Flame detected, Weak flame, Main burner on
Red LED Indications During Error Operation
1 Flash, then pause Flame Error Lockout
3 Flashes, then pause Gas Valve Error Lockout
4 Flashes, then pause Line Voltage/Frequency Error Standby
5 Flashes, then pause Internal Control Error Lockout